Power System. Part II / (Record no. 26652)

000 -LEADER
fixed length control field 03415 a2200181 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230623b ||||| |||| 00| 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number 9789390770755
Terms of availability Rs495.00
082 00 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 621.31
Item number B169
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Bakshi, U. A.
9 (RLIN) 5547
245 ## - TITLE STATEMENT
Title Power System. Part II /
250 ## - EDITION STATEMENT
Edition statement 1st ed.
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Place of publication, distribution, etc Pune:
Name of publisher, distributor, etc Technical Publications,
Date of publication, distribution, etc 2022.
300 ## - PHYSICAL DESCRIPTION
Extent xii, s-2 p. :
Other physical details ill. ;
Dimensions 25 cm
520 ## - SUMMARY, ETC.
Summary, etc 1. Basic Principles : Power in single phase AC circuits, Complex power, Complex power balance, Complex power flow, Balanced Three Phase Circuits, Star connected loads, Delta connected loads, Delta-star transformation, Per phase analysis, Balanced three phase power. (Chapter - 1) 2. Representation of Power System Components : One line and impedance diagram, Per unit system, Per unit representation of transformer, Per unit impedance diagram of power system, Examples - per unit system and impedance diagram, Synchronous machine, Power factor and power control, Salient pole synchronous generator, Operating chart of a synchronous generator, Representation of loads. (Chapter - 2) 3. Transmission Line Modeling and Performance : Introduction, Short transmission line, Medium transmission line, Long transmission line - Rigorous solution, Evaluation of ABCD constants, Interpretation of long line equations, Ferranti effect, Tuned power lines, Power through a transmission line, Circle diagrams, Methods of voltage control, Examples. (Chapter - 3) 4. Symmetrical Fault Analysis : Introduction, Transient on a transmission line, Short circuit of a synchronous machine on no load, short circuit of a loaded synchronous machine, Selection of circuit breakers, Examples, ZBUS formulation - by inverting YBUS, current injection technique, ZBUS building algorithm (Type - 1, 2, 3, 4 modifications). (Chapter - 4) 5. Symmetrical Components : Symmetrical component transformation, Phase shift in star-delta transformers, Sequence impedances of transmission lines, Sequence - impedances and networks of synchronous machines, Sequence impedances and networks of transformers, Construction of sequence networks of a power system, Examples. (Chapter - 5) 6. Unsymmetrical Fault Analysis : Introduction, Symmetrical component analysis of unsymmetrical faults, Single line to ground fault, Line to line fault, Double line to ground fault, Open conductor faults. (Chapter - 6) 7. Corona : Critical Disruptive Voltage, Corona Loss, Line Design based on Corona, Disadvantages of Corona, Radio Interference, Inductive interference between Power and Communication lines, Examples. (Chapter - 7) 8. Over-voltages in Power Systems : Causes of over-voltages, Internal causes of over-voltages, Mechanism of lightning discharge, Types of lightning strokes, Harmful effects of lightning, Protection against lightning, Earthing screen, Overhead ground wires, Lightning arresters, Surge absorber. (Chapter - 8) 9. Transients in Power Systems : Travelling waves on transmission lines, Open end line, Short circuited line, Line terminated through a resistance, Line connected to a cable, Reflection and refraction at a T-junction, Line terminated through a capacitance, capacitor connection at T, Attenuation of travelling waves. Capacitance switching, Over-voltages due to arcing ground. (Chapter - 9)
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name as entry element Electric Power Engineering
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 5553
Personal name Sansare, Vaibhav A.
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Item type Books
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent location Current location Shelving location Date acquired Source of acquisition Cost, normal purchase price Full call number Barcode Date last seen Cost, replacement price Koha item type Total Checkouts Checked out Date last borrowed
          IMU Kolkata IMU Kolkata Reference 2023-06-23 4 389.74 621.31 B169 14121 2023-06-23 520.00 Books      
          IMU Kolkata IMU Kolkata   2023-06-23 4 389.74 621.31 B169 14123 2023-06-23 520.00 Books      
          IMU Kolkata IMU Kolkata   2023-06-23 4 389.74 621.31 B169 14125 2023-06-23 520.00 Books      
          IMU Kolkata IMU Kolkata   2023-06-23 4 389.74 621.31 B169 14127 2024-08-14 520.00 Books 2 2025-02-10 2024-08-14
Designed and Maintained by IMU-KC Library, Kolkata Campus © Copyright All Rights Reserved

webs counters

Powered by Koha